Our product

agilent liner selection guide

agilent liner selection guide

  • Selecting the Correct Inlet Liner - 7890A GC Agilent

    Information for selecting the correct split / splitless injection port liner for an Agilent 7890A GC

  • Gas Chromatography Liner Selection Guide

    Gas Chromatography Liner Selection Guide Peter Morgan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Introduction When developing a new method, liner selection can be overlooked due to the number of other parameters that need to be considered. Selecting the wrong liner will lead to poor separation, which could be wrongly attributed to

  • pittcon Choosing the Correct Liner Liner - agilent

    Page 2 Agilent Confidential Introduction Choosing the correct liner for a particular application must take several variables into account. Variables to consider include matching the liner to the injection type, matching the injection volume to the volume of the liner, determine if a vaporization

  • Inlet Liners for Varian/Bruker GC Systems Agilent

    Agilent inlet liners for Varian/Bruker GC Systems provide the optimum environment for samples to be vaporized and mixed with the carrier gas in the inlet system. Agilent inlet liners have the perfect mix of liner configurations and chemistries to solve a wide range of application challenges when using Varian/Bruker GC systems. Choose from split ...

  • Split Liners Agilent

    Agilent split liners are made to strict dimension specifications for optimal inlet performance and feature the tightest tolerances for od, id, taper and glass wool placement.

  • Bulletin 899A Capillary GC Inlet Liner Selection Guide

    Bulletin 899A Capillary GC Inlet Liner Selection Guide Four injection techniques – split, splitless, direct, and on-column – are used in capillary gas chromatography. Each of these techniques, and their uses, are described in this guide. Also described are various designs of inlet liners

  • GC Supplies - Agilent Instrument Quick Pick Guide

    GC Supplies - Agilent Instrument Quick Pick Guide • Syringes • Septa • Inlet Liners • O-rings • Ferrules • SilTiteTM FingerTite Ferrules • Electron Multipliers. 1 Instrument Quick Pick for Agilent Technologies Autosampler Syringes All needles are 42 mm long with a cone point. Agilent 7673, 7683 6850 ALS Volume Needle Gauge (OD mm) Syringe Code Syringe Part No. Pack Size Spare ...

  • How to Choose a GC Inlet Liner:Simplify Selection Based on ...

    How do you choose the GC inlet liner that’s best for your application? With so many options available, selecting the right liner can be a daunting task. In this technical article, Restek makes it easy to choose the best GC inlet liner for each injection technique. Read on and learn how to simplify liner selection!

  • Selecting the Right Inlet Liner for Efficient Sample Transfer

    expands is determined by the solvent, the inlet temperature, and the pressure inside the liner. See table. Your liner volume needs to be large enough to accommodate the gaseous sample. If the diameter is too small, the sample will expand beyond the liner’s capacity—causing sample loss through the septum purge flow and split line. When the ...

  • The Right Parts Make All the Difference

    Quick Guide for Agilent Split/Splitless Replacement Parts and Supplies The Right Parts Make All the Difference. 2 How to Choose the Right Split/Splitless Parts Authentic Agilent Replacement Parts and Supplies Item/Part Number* Advantages When to Use Example Septa Type Bleed and Temperature Optimized Septa Center point recess allows for easy In applications with inlet temperatures Analyses

  • How to Choose a GC Inlet Liner: Simplify Selection Based ...

    With Topaz inlet liners, the wool is deactivated in situ, making for a very inert liner, which will work well for the majority of split injection applications. Long gone is the issue of liner activity being caused by wool. General Applications How to Choose a GC Inlet Liner: Simplify Selection Based on Injection Type By Scott Adams Pure ...

  • Agilent Technologies Liners - SGE Analytical Science

    RoHS Compliant with specific application listed in the Annex to 2002/95/EC Directive. Compliant Certificate - products listed on this page are RoHS compliant with specific application listed in the Annex to 2002/95/EC Directive

  • Capillary GC Liner Selection Guide - Crawford Scientific Ltd

    I’ve always thought that a simple guide to liner selection for capillary gas chromatography was a good idea. The internet is packed with information from vendors on which type of liner to use, however there is a tendency to push their latest greatest design, or explain the function of a whole bunch of historical designs which frankly are no longer required, due to improvements in instrument ...

  • Find a product () Agilent

    Agilent CrossLab supplies are backed by a risk-free warranty that they are compatible with other instrument brands. In the unlikely event of a problem, we guarantee:

  • Agilent Column Selection Guide - Options

    What can we help you with? Choose from these options to narrow your search. Option 1: I already have a column or sample prep method. Option 2: Column recommendation based on method parameters.

  • CrossLab Selection Guide Cover - Cromlab

    2 Agilent CrossLabSelection Guide CrossLab Product Introductions CrossLab Inlet Liners Considerthefollowingtodetermine howoftentochangeyourliners ...

  • Inlet Liners and Sealing Systems from Agilent

    Inlet Liners and Sealing Systems from Agilent. Liners are the centerpiece of the inlet system where sample is vaporized and mixed with the carrier gas. Agilent GC liners have the perfect mix of liner configurations and chemistries to solve your application challenges.

  • Agilent ultra Inert Liners - Analytics Shop

    Agilent ultra Inert Liners Agilent Ultra Inert liners are the perfect companion to Agilent JW Ultra Inert GC columns. They provide reproducible inertness liner after liner, maintained through a sequence of samples, and for a range of analytes. Agilent's Ultra Inert liners were developed –

  • Agilent CrossLab Selection Guide for GC Systems CrossLab

    CrossLab Liner O-rings ... 18 Agilent CrossLabSelection Guide CrossLab Supplies for PerkinElmer GC Systems DirectLiners Gooseneck,drilledhole ontop,wool 4.0 6.2 92.1 5/pk 8003-0155 OtherLiners Packedcolumn,straight 3.0 6.2 112 800 5/pk 8003-0163 8003-0108 Programmableon-column,hourglass 2.2 4.0 16 5/pk 8003-0109* PTV,0.25mmID restriction,recessed gooseneck 1.0 2.0 88 70 5/pk 8003

  • Choose for Your Instrument GC Supplies - Agilent ...

    Choose for Your Instrument GC Supplies - Agilent Instrument Quick Pick Guide • Syringes • Septa • Inlet Liners • O-rings and Sealing Rings • SilTite ® FingerTite Ferrules • Ferrules. Your chromatography analysis does not end with the selection of the GC column. The combination of components selected for your instrument also make an important contribution to successful separations ...

  • Choose for Your Instrument GC Supplies - Agilent ...

    Choose for Your Instrument GC Supplies - Agilent Instrument Quick Pick Guide • Syringes • Septa • Inlet Liners • O-rings and Sealing Rings • SilTite ® FingerTite Ferrules • Ferrules. Your chromatography analysis does not end with the selection of the GC column. The combination of components selected for your instrument also make an important contribution to successful separations ...

  • Inlet Liners Liner Supplies / GC Accessories / Supplies ...

    Topaz 4.0 mm ID Low Pressure Drop Precision Inlet Liner w/ Wool for Agilent GCs equipped with split/splitless inlets. Topaz GC inlet liners feature revolutionary technology and inertness to deliver you the next level of True Blue Performance: Deactivation—unbelievably low breakdown for accurate and precise low-level GC analyses. Reproducibility—unbeatable manufacturing controls and QC ...

  • GC - Phenomenex

    Part number cross-referencing service available – just contact a GC Specialist! Download the Liner Selection Chart » View liners by type: Instrument Manufacturer Agilent » Shimadzu » Thermo Scientific » PerkinElmer » Varian » Liner Style Straight » FocusLiner » Direct Connect » Single Taper » Dual Taper » Gooseneck » Cup Splitter » with Glass Wool » Injection Type for Split ...

  • Technical Tips: Choosing the Right GC Inlet Liner

    how do you choose the right inlet liner for your analysis? Each style of inlet liner offers a different range of benefits – to get the best performance, the key is to choose a liner that is well-suited for your injection type, sample, and budget. Below is a basic overview of liner styles.

  • GC Injection Port Liners Products and Chromatography ...

    Use these injection port liners to optimize performance of Agilent GC instruments. Use the gold-standard LinerGOLD™ GC Liners for consistently high accuracy, sensitivity, and precision in your gas chromatography (GC) analysis. Injection Port Liners with CarboFrit for Thermo Scientific™ Trace and

  • SGE Product Selection Guide 50 Years Edition

    Inlet Liner Selection 151-157 Connections, Ferrules and Unions 158 Ferrules 158-161 SilTite™ FingerTite 159 Unions 161-164 Nuts for SGE Fittings 164-165 Gas Purifiers for GC 165-166 Instrument Quick Pick Guide 167 Agilent Technologies 167-170 PerkinElmer 170-172 Shimadzu 172-174 Thermo Scientific 175-177 Varian / Bruker 177-180 ATAS Optic ...

  • Guide to GC Column Selection and Optimizing Separations ...

    Guide to GC Column Selection and Optimizing Separations • Learn how to choose the right column the first time. • Optimize separations for the best balance of resolution and speed. • Troubleshoot quickly and effectively based on chromatographic symptoms. Pure Chromatography. restek

  • Choisissez selon votre appareil Guide de sélection rapide ...

    Guide de sélection rapide pour appareil — Consommables de GC • Agilent Technologies • Bruker (Varian) • PerkinElmer • Shimadzu • Thermo Scientific sge Choisissez selon votre appareil. Votre analyse de chromatographie ne s’arrête pas à la sélection de la colonne GC. La combinaison de composants sélectionnés pour votre appareil apporte aussi une contribution ...

  • Agilent 6400 Series Triple Quad LC/MS

    6400 Series Triple Quad LC/MS Maintenance Guide 3 Contents 1 Maintenance 7 Calibrant Delivery System and Divert Valve 8 To prepare the reference mass solution 11 To check calibrant levels 14 To fill a calibrant bottle 15 To check for leaks16 To replace the LC filter elements 17 To replace the MS selection valve rotor seal 18 Electrospray Ion Source 20 To flush the nebulizer 20 To clean the ...

  • Agilent GC Column Installation Video GC

    2013-08-11  Agilent GC Column Installation Video GC Troubleshooting Series 24yogeshk. Loading... Unsubscribe from 24yogeshk? Cancel Unsubscribe. Working... Subscribe Subscribed Unsubscribe 909. Loading ...